ARCHETYPE ID | openEHR-EHR-CLUSTER.device_details.v0 |
Concept | Medical device details |
Description | Specific details that relate to asset management for any medical device that is designed for more than a single use. |
Use | Use to record details about durable or persisting medical device. This archetype is designed to be used in the 'Asset Management' SLOT within the CLUSTER.device archetypes and/or any specialisations of this archetype. |
Misuse | Not to be used outside of the CLUSTER.device archetype or its specialisations, unless there is a clear identification of the device about which the information is being recorded. |
Purpose | To record details that can be used to support asset management for any durable or persisting medical device. For example, information about: the physical location of the device; its network URL; and maintenance, service, cleaning, and calibration details. |
References | Resource Device [Internet]. HL7 International, FHIR Specification first DSTU version (v 0.0.82). Available from: http://www.hl7.org/implement/standards/fhir/device.html [last accessed 25 Feb 2015]. Implementation Guide for CDA Release 2.0 Personal Healthcare Monitoring Report (PHMR) (International Realm) Draft Standard for Trial Use Release 1. HL7 International, 2008. Available at: http://wiki.hl7.org/index.php?title=Product_CDA_R2_IG#Product_Name_-_CDA_R2_IG_PHM_Reports [last accessed 05 Mar 2015]. Guidelines for 64-bit Global Identifier (EUI-64) [Internet]. IEEE Standards Association [cited: 2015-02-25]. Available from: http://standards.ieee.org/regauth/oui/tutorials/EUI64.html [last accessed 05 Mar 2015]. |
Copyright | © openEHR Foundation |
Authors | Nom de l'autor: Heather Leslie Organització: Atomica Informatics Correu electrònic: heather.leslie@atomicainformatics.com Data d'autor original: 2010-08-16 |
Other Details Language | Nom de l'autor: Heather Leslie Organització: Atomica Informatics Correu electrònic: heather.leslie@atomicainformatics.com Data d'autor original: 2010-08-16 |
OtherDetails Language Independent | {licence=This work is licensed under the Creative Commons Attribution-ShareAlike 3.0 License. To view a copy of this license, visit http://creativecommons.org/licenses/by-sa/3.0/., custodian_organisation=openEHR Foundation, references=Resource Device [Internet]. HL7 International, FHIR Specification first DSTU version (v 0.0.82). Available from: http://www.hl7.org/implement/standards/fhir/device.html [last accessed 25 Feb 2015]. Implementation Guide for CDA Release 2.0 Personal Healthcare Monitoring Report (PHMR) (International Realm) Draft Standard for Trial Use Release 1. HL7 International, 2008. Available at: http://wiki.hl7.org/index.php?title=Product_CDA_R2_IG#Product_Name_-_CDA_R2_IG_PHM_Reports [last accessed 05 Mar 2015]. Guidelines for 64-bit Global Identifier (EUI-64) [Internet]. IEEE Standards Association [cited: 2015-02-25]. Available from: http://standards.ieee.org/regauth/oui/tutorials/EUI64.html [last accessed 05 Mar 2015]., current_contact=Heather Leslie, Ocean Informatics, heather.leslie@oceaninformatics.com, original_namespace=org.openehr, original_publisher=openEHR Foundation, custodian_namespace=org.openehr, MD5-CAM-1.0.1=A585C08AA295D79F2248D2E61472C89C, build_uid=41f9352f-9d5b-4a60-a34a-a2c8f43da327, revision=0.0.1-alpha} |
Keywords | calibration, maintenance, sterilization, cleaned, service, device |
Lifecycle | in_development |
UID | 9cf4152b-3fe8-4f5a-9806-999d797a3c55 |
Language used | en |
Citeable Identifier | 1380.146.272 |
Revision Number | 0.0.1-alpha |
All | Archetype [runtimeNameConstraintForConceptName=null, archetypeConceptBinding=null, archetypeConceptDescription=Specific details that relate to asset management for any medical device that is designed for more than a single use., archetypeConceptComment=null, otherContributors=Ian McNicoll, freshEHR Consulting, United Kingdom, originalLanguage=en, translators=
Tots arquetips no exclosos explícitament, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0018], code=at0018, itemType=SLOT, level=1, text=Serviced by, description=Details of agent who performed the servicing., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Opcional, repetint, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Incloure: Tots arquetips no exclosos explícitament, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0007], code=at0007, itemType=ELEMENT, level=1, text=Part number, description=The part number of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=ELEMENT, level=1, text=Manufacturer model name, description=HL7 CDA compatible representation of device manufacture details., comment=May be a simple string or contain simple markup e.g. for Continua PHMR reports: "Pulse Master 2000||584216|69854|2.1|1.1|1.0|" repesenting Model, Unspecified, SerialNumber, PartNumber, HardwareRevision, SoftwareRevision, ProtocolRevision, and ProdSpecGMDN., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0008], code=at0008, itemType=ELEMENT, level=1, text=Hardware revision, description=The hardware revision number., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0010], code=at0010, itemType=ELEMENT, level=1, text=Protocol revision, description=The protocol revision number., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0011], code=at0011, itemType=ELEMENT, level=1, text=Sampling frequency, description=The sampling frequency limits of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=Elecció de:
Tots arquetips no exclosos explícitament, extendedValues=null]], ism_transition=[], events=[], relationships=[], context=[], provider=[], identities=[], target=[], credentials=[], source=[], capabilities=[], data=[], state=[], protocol=[], activities=[]}, topLevelItems={items=ResourceSimplifiedHierarchyItem [path=ROOT_/, code=at0000, itemType=CLUSTER, level=0, text=null, description=null, comment=null, uncommonOntologyItems=null, occurencesFormal=1..1, occurencesText=Obligatòria, cardinalityFormal=1..*, cardinalityText= , subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=null, extendedValues=null]}, addHierarchyItemsTo=items, currentHierarchyItemsForAdding=[ResourceSimplifiedHierarchyItem [path=/items[at0001], code=at0001, itemType=ELEMENT, level=1, text=Organisation identifier, description=Organisation identifier for device., comment=May be a text string or an IEEE EUI-64 identifier., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=Elecció de:
Tots arquetips no exclosos explícitament, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0018], code=at0018, itemType=SLOT, level=1, text=Serviced by, description=Details of agent who performed the servicing., comment=null, uncommonOntologyItems=null, occurencesFormal=0..*, occurencesText=Opcional, repetint, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CLUSTER, bindings=null, values=Incloure: Tots arquetips no exclosos explícitament, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0007], code=at0007, itemType=ELEMENT, level=1, text=Part number, description=The part number of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0002], code=at0002, itemType=ELEMENT, level=1, text=Manufacturer model name, description=HL7 CDA compatible representation of device manufacture details., comment=May be a simple string or contain simple markup e.g. for Continua PHMR reports: "Pulse Master 2000||584216|69854|2.1|1.1|1.0|" repesenting Model, Unspecified, SerialNumber, PartNumber, HardwareRevision, SoftwareRevision, ProtocolRevision, and ProdSpecGMDN., uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0008], code=at0008, itemType=ELEMENT, level=1, text=Hardware revision, description=The hardware revision number., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0010], code=at0010, itemType=ELEMENT, level=1, text=Protocol revision, description=The protocol revision number., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=DV_TEXT, bindings=null, values=, extendedValues=null], ResourceSimplifiedHierarchyItem [path=/items[at0011], code=at0011, itemType=ELEMENT, level=1, text=Sampling frequency, description=The sampling frequency limits of the device., comment=null, uncommonOntologyItems=null, occurencesFormal=0..1, occurencesText=Opcional, cardinalityFormal=null, cardinalityText=null, subCardinalityFormal=null, subCardinalityText=null, dataType=CHOICE, bindings=null, values=Elecció de:
Tots arquetips no exclosos explícitament, extendedValues=null]], minIndents={}, termBindingRetrievalErrorMessage=null] |